All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Research

, Volume: 22( 11) DOI: DOI:10.37532/0974-7419.2022.22(11).223

ELECTROCHEMICAL DETECTION OF SOME WATER SOLUBLE AND FAT SOLUBLE VITAMINS BY USING BARE PENCIL GRAPHITE ELECTRODE

Tolga Saruhan1*, Perihan Adun2, ?hsan Erol Özçil1

1American University of Cyprus, Faculty of Business and Economics, Department of Tourism Management.

2Near East University, Faculty of Engineering, Department of Food Engineering.

*Corresponding author: Tolga Saruhan American University of Cyprus, Faculty of Business and Economics, Department of Tourism Management, Cyprus. Email ID: tolgasaruhann@gmail.com.

Received: November 08, 2022, Manuscript No. tsac-22-79320; Editor assigned: November 11, 2022, PreQC No. tsac-22-79320 (PQ); Reviewed: November 11, 2022, QC Notsac-22-79320 (Q); Revised: November 13, 2022, Manuscript No tsac-22-79320 (R); Published date: November 27, 2022. DOI:10.37532/0974-7419.2022.22(11).223

Abstract

Vitamins are a group of organic compounds needed in small quantities by the body to perform its essential functions like growing, regulating metabolism and maintain a healthy immune system. In recent years, substantial efforts have been focused on development of simplified, fast and cost-effective approaches for vitamin analysis. Aim of this study was electrochemical detection of some water and fat-soluble vitamins individually and simultaneously by using bare Pencil Graphite Electrode (PGE). Vitamins of C, B1, B6, B12, A, D3, and E were selected and electrochemically analyzed in pharmaceutical perpetrates. Simultaneous analysis of water-soluble vitamins by using DPV with PGE can be promising technique for the determination of vitamin C and B6 or vitamin B1, B12 and B6. In the case of fat-soluble vitamins, resolution between vitamin D3 and E was not satisfactory. However, vitamin A and D or vitamin A and E could be detected in a single run. Limit of detection of the selected vitamins were quite low (4-548 µg/ml).

Retraction note

The article entitled “ELECTROCHEMICAL DETECTION OF SOME WATER SOLUBLE AND FAT SOLUBLE VITAMINS BY USING BARE PENCIL GRAPHITE ELECTRODE Retracted: had been accepted for publication in the Analytical chemistry: an Indian journal considering the statements provided in the article as the personal opinion of the author to be completely unbiased. The article was published solely on the basis of the opinion provided by the reviewers. But due to some unforeseen divergences between the author and the journal, the article is being retracted.

Awards Nomination 20+ Million Readerbase

Table of Contents

Google Scholar citation report
Citations : 378

Analytical Chemistry: An Indian Journal received 378 citations as per Google Scholar report

Indexed In

  • CASS
  • Google Scholar
  • Open J Gate
  • China National Knowledge Infrastructure (CNKI)
  • CiteFactor
  • Cosmos IF
  • Electronic Journals Library
  • Directory of Research Journal Indexing (DRJI)
  • Secret Search Engine Labs
  • ICMJE

View More

Flyer
rolex replica