All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Abstract

Stability indicatingHPLC-determination of biperiden hydrochloride in presence of its oxidative and acid degradation products

Author(s): Hayam M.Lotfy, Ezzat M.Abdel-Moety, Eman G.Nouman

A RP-HPLC method for stability indicating determination of biperiden hydrochloride (BIPER) in presence of its oxidative and /or acid degradation products, was developed, optimized, validated and appiled either in tablets dosage form or in raw materials. The separation could be acheived on a reversed phase column [NucleodureC18 (5m, 25 cmx 4.6mmi.d.)] isocratically by using amixture of 0.2%0.1N perchloric acid in 0.01Msodiumperchlorate solution and acetonitrile in a ratio (50 : 50% v/v) as the mobile phase withUV-detection at 210 nm. Significant linearitywas observed in the ranges of 8-100gmL-1. Statistical evaluation of the resultswas obtained by adopting the proposed method and those of reference ones has been undertaken by applying the student t-testing, F-ratio calculation and by one-way ANOVAassessment.